AKP Series of Wave Soldering Machine

● New solution of preheating:

The hot air preheating u- shaped heater has a long service life, and reduces maintenance downtime. Internal reinforcement insulation plus an optional external protection device can effectively reduce the heat loss, energy-saving up to 20% compared with traditional equipment. Lower body temperature with better work enviroment.

● External Spray Fluxer, safety, cost, space, and maintenance problems resolved:

External and independent spray control system, ensure the safety and clean, easy to operate and maintenance; Transportation of new type titanium alloy heavy-duty claw, sectional guide rail design, stainless steel strip supported in guide rail, long life; The solder pot adopts special materials, Anti corrosion coating on surface; Adopt imported precision nozzle, atomization uniformity, high efficient.

● The large promotion of solder pot:

Nozzle quick released, reduce maintenance time, 2 hours to a few minutes; Grid type of mesh, reduce the mesh block by solder dross monthly maintenance extended to six months; Optional auto solder supplying device, reduce the influence of wave height caused by a drop of solder level;

Share to:

MODEL No. 350 Series
AKP-350-M
Wave Soldering Outside Dimension(L*W*H) 3945×1582×1735mm
External Spray Fluxer Outside Dimension(L*W*H) 1300×1350×1595mm
Power Supply 3P5W 380V AC 50/60Hz
Option:3P5W 220V AC 50/60Hz
Operating Power ≤9KW
Power For Warm Up 30KW
Air 0.5Mpa-0.8Mpa Air
Control Mode PC+PLC
Spray Flow 10~100ml/min
Exhaust Pipe Diameter Φ200mm
Air Outlet Mode Up-down Convection
Preheat Mode Hot Air Preheating / Infrared Preheating
Preheat Zones Number 3 Zones 
Preheat Temperature Room Temperature~230℃
Preheating Temperature Control Mode PID+SSR
Working Mode of Tin Furnace Mechanical Pump
Tin Furnace Capacity Lead-free: About 480KG
MAX Temp of Tin Furnace MAX: 300℃
Wave Driving Power 1/4 HP×2 
Warming Up Time About 140 min(Setting Temperature:265℃)
PCB Transmission Speed 300~1800mm/min
Width Range of PCB 50-350mm
PCB Board Component Height Top 120mm, Bottom 25mm
PCB Inlet Transport Height 750±20mm
Transport Guide Rail Inclination Factory:5.5°±0.2°(4°— 7°Adjustable )
Cooling Mode Forced Air Cooling
Nitrogen Consumption 15m³/h below 2000ppm以下
Pressure Nitrogen Source 0.5~0.8MPa
Oxygen Nitrogen Source ≤10PPM
Oxygen Analyzer option
The above contents are subject to change without further notice!

AKP-350-H

MODEL No. 350 Series
AKP-350 H
Wave Soldering Outside Dimension(L*W*H) 4445×1582×1735mm
External Spray Fluxer Outside Dimension(L*W*H) 1300×1350×1595mm
Power Supply 3P5W 380V AC 50/60Hz 
Option: 3P5W 220V AC 50/60Hz 
Operating Power ≤11KW
Power For Warm Up 30KW
Air 0.5Mpa-0.8Mpa Air
Control Mode PC+PLC
Spray Flow 10~100ml/min
Exhaust Pipe Diameter Φ200mm
Air Outlet Mode Up-down Convection
Preheat Mode Hot Air Preheating / Infrared Preheating
Preheat Zones Number 4 Zones 
Preheat Temperature Room Temperature~250℃
Preheating Temperature Control Mode PID+SSR
Working Mode of Tin Furnace Mechanical Pump
Tin Furnace Capacity Lead-free: About 480KG
MAX Temp of Tin Furnace MAX: 300℃
Wave Driving Power 1/4 HP×2 
Warming Up Time About 140 min(Setting Temperature:265℃)
PCB Transmission Speed 300~1800mm/min
Width Range of PCB 50-350mm
PCB Board Component Height Top 120mm, Bottom 25mm
PCB Inlet Transport Height 750±20mm
Transport Guide Rail Inclination Factory:5.5°±0.2°(4°— 7°Adjustable )
Cooling Mode Forced Air Cooling
Nitrogen Consumption 15m³/h below 2000ppm以下
Pressure Nitrogen Source 0.5~0.8MPa
Oxygen Nitrogen Source ≤10PPM
Oxygen Analyzer option
The above contents are subject to change without further notice!

AKP-450-M

<table style=”width: 1070px;” width=”1595″>
<tbody>
<tr>
<td style=”width: 445.609px;” rowspan=”2″ width=”214″>MODEL No.</td>
<td style=”width: 617.391px;” width=”549″>450 Series</td>
</tr>
<tr>
<td style=”width: 617.391px;” width=”279″>AKP-450-M</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Wave Soldering Outside Dimension(L*W*H)</td>
<td style=”width: 617.391px;” width=”279″>3945&times;1582&times;1735mm</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>External Spray Fluxer Outside Dimension(L*W*H)</td>
<td style=”width: 617.391px;” width=”1106″>1300&times;1350&times;1595mm</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Power Supply</td>
<td style=”width: 617.391px;” width=”279″>3P5W 380V AC 50/60Hz<br />Option: 3P5W 220V AC 50/60Hz&nbsp;</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Operating Power</td>
<td style=”width: 617.391px;” width=”279″>&le;10KW</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Power For Warm Up</td>
<td style=”width: 617.391px;” width=”1106″>30KW</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Air</td>
<td style=”width: 617.391px;” width=”1381″>0.5Mpa-0.8Mpa Air</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Control Mode</td>
<td style=”width: 617.391px;” width=”1381″>PC+PLC</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Spray Flow</td>
<td style=”width: 617.391px;” width=”1381″>10~100ml/min</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Exhaust Pipe Diameter</td>
<td style=”width: 617.391px;” width=”1381″>&Phi;200mm</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Air Outlet Mode</td>
<td style=”width: 617.391px;” width=”1381″>Up-down Convection</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Preheat Mode</td>
<td style=”width: 617.391px;” width=”1381″>Hot Air Preheating / Infrared Preheating</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Preheat Zones Number</td>
<td style=”width: 617.391px;” width=”279″>3 Zones&nbsp;</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Preheat Temperature</td>
<td style=”width: 617.391px;” width=”279″>Room Temperature~230℃</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Preheating Temperature Control Mode</td>
<td style=”width: 617.391px;” width=”1381″>PID+SSR</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Working Mode of Tin Furnace</td>
<td style=”width: 617.391px;” width=”1381″>Mechanical Pump</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Tin Furnace Capacity</td>
<td style=”width: 617.391px;” width=”549″>Lead-free: About 550KG</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>MAX Temp of Tin Furnace</td>
<td style=”width: 617.391px;” width=”1381″>MAX: 300℃</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Wave Driving Power</td>
<td style=”width: 617.391px;” width=”549″>1/2 HP&times;2&nbsp;</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Warming Up Time</td>
<td style=”width: 617.391px;” width=”549″>About 150 min(Setting Temperature:265℃)</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>PCB Transmission Speed</td>
<td style=”width: 617.391px;” width=”1381″>300~1800mm/min</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Width Range of PCB</td>
<td style=”width: 617.391px;” width=”549″>50-450mm</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>PCB Board Component Height</td>
<td style=”width: 617.391px;” width=”1381″>Top 120mm, Bottom 25mm</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>PCB Inlet Transport Height</td>
<td style=”width: 617.391px;” width=”1381″>750&plusmn;20mm</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Transport Guide Rail Inclination</td>
<td style=”width: 617.391px;” width=”1381″>Factory:5.5&deg;&plusmn;0.2&deg;(4&deg;&mdash; 7&deg;Adjustable )</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Cooling Mode</td>
<td style=”width: 617.391px;” width=”1381″>Forced Air Cooling</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Nitrogen Consumption</td>
<td style=”width: 617.391px;” width=”1381″>15m&sup3;/h below 2000ppm以下</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Pressure Nitrogen Source</td>
<td style=”width: 617.391px;” width=”1381″>0.5~0.8MPa</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Oxygen Nitrogen Source</td>
<td style=”width: 617.391px;” width=”1381″>&le;10PPM</td>
</tr>
<tr>
<td style=”width: 445.609px;” width=”214″>Oxygen Analyzer</td>
<td style=”width: 617.391px;” width=”1381″>option</td>
</tr>
<tr>
<td style=”width: 1063px;” colspan=”2″>The above contents are subject to change without further notice!</td>
</tr>
</tbody>
</table>

AKP-450-H

<table style=”width: 1081px; height: 674px;” width=”1595″>
<tbody>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 42px;” rowspan=”2″ width=”214″>MODEL No.</td>
<td style=”width: 634.922px; height: 21px;” width=”549″>450 Series</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 634.922px; height: 21px;” width=”270″>AKP-450-H</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Wave Soldering Outside Dimension(L*W*H)</td>
<td style=”width: 634.922px; height: 21px;” width=”270″>4445&times;1582&times;1735mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>External Spray Fluxer Outside Dimension(L*W*H)</td>
<td style=”width: 634.922px; height: 21px;” width=”1106″>1300&times;1350&times;1595mm</td>
</tr>
<tr style=”height: 42px;”>
<td style=”width: 439.078px; height: 42px;” width=”214″>Power Supply</td>
<td style=”width: 634.922px; height: 42px;” width=”270″>3P5W 380V AC 50/60Hz<br />Option: 3P5W 220V AC 50/60Hz&nbsp;</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Operating Power</td>
<td style=”width: 634.922px; height: 21px;” width=”270″>&le;12KW</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Power For Warm Up</td>
<td style=”width: 634.922px; height: 21px;” width=”1106″>30KW</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Air</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>0.5Mpa-0.8Mpa Air</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Control Mode</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>PC+PLC</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Spray Flow</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>10~100ml/min</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Exhaust Pipe Diameter</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>&Phi;200mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Air Outlet Mode</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>Up-down Convection</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Preheat Mode</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>Hot Air Preheating / Infrared Preheating</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Preheat Zones Number</td>
<td style=”width: 634.922px; height: 21px;” width=”270″>4 Zones&nbsp;</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Preheat Temperature</td>
<td style=”width: 634.922px; height: 21px;” width=”270″>Room Temperature~250℃</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Preheating Temperature Control Mode</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>PID+SSR</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Working Mode of Tin Furnace</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>Mechanical Pump</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Tin Furnace Capacity</td>
<td style=”width: 634.922px; height: 21px;” width=”549″>Lead-free: About 550KG</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>MAX Temp of Tin Furnace</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>MAX: 300℃</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Wave Driving Power</td>
<td style=”width: 634.922px; height: 21px;” width=”549″>1/2 HP&times;2&nbsp;&nbsp;</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Warming Up Time</td>
<td style=”width: 634.922px; height: 21px;” width=”549″>About 150 min(Setting Temperature:265℃)</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>PCB Transmission Speed</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>300~1800mm/min</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Width Range of PCB</td>
<td style=”width: 634.922px; height: 21px;” width=”549″>50-450mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>PCB Board Component Height</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>Top 120mm, Bottom 25mm</td>
</tr>
<tr style=”height: 23px;”>
<td style=”width: 439.078px; height: 23px;” width=”214″>PCB Inlet Transport Height</td>
<td style=”width: 634.922px; height: 23px;” width=”1381″>750&plusmn;20mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Transport Guide Rail Inclination</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>Factory:5.5&deg;&plusmn;0.2&deg;(4&deg;&mdash; 7&deg;Adjustable )</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Cooling Mode</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>Forced Air Cooling</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Nitrogen Consumption</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>15m&sup3;/h below 2000ppm以下</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Pressure Nitrogen Source</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>0.5~0.8MPa</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Oxygen Nitrogen Source</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>&le;10PPM</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 439.078px; height: 21px;” width=”214″>Oxygen Analyzer</td>
<td style=”width: 634.922px; height: 21px;” width=”1381″>option</td>
</tr>
<tr>
<td style=”width: 1074px;” colspan=”2″>The above contents are subject to change without further notice!</td>
</tr>
</tbody>
</table>

AKP-610-H

<table style=”width: 1130px; height: 677px;” width=”1595″>
<tbody>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 42px;” rowspan=”2″ width=”214″>MODEL No.</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>610 Series</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 680.812px; height: 21px;” width=”275″>AKP-610-H</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Wave Soldering Outside Dimension(L*W*H)</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>4645&times;1742&times;1735mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>External Spray Fluxer Outside Dimension(L*W*H)</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>1400&times;1510&times;1595mm</td>
</tr>
<tr style=”height: 42px;”>
<td style=”width: 442.188px; height: 42px;” width=”214″>Power Supply</td>
<td style=”width: 680.812px; height: 42px;” width=”275″>3P5W 380V AC 50/60Hz&nbsp;<br />Option: 3P5W 220V AC 50/60Hz</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Operating Power</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>&le;13.5KW</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Power For Warm Up</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>40KW</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Air</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>0.5Mpa-0.8Mpa Air</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Control Mode</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>PC+PLC</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Spray Flow</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>10~100ml/min</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Exhaust Pipe Diameter</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>&Phi;200mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Air Outlet Mode</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>Up-down Convection</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Preheat Mode</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>Hot Air Preheating / Infrared Preheating</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Preheat Zones Number</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>4 Zones&nbsp; &nbsp;</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Preheat Temperature</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>Room Temperature~280℃</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Preheating Temperature Control Mode</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>PID+SSR</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Working Mode of Tin Furnace</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>Mechanical Pump</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Tin Furnace Capacity</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>Lead-free: About 800KG</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>MAX Temp of Tin Furnace</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>MAX: 300℃</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Wave Driving Power</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>1/2 HP&times;1+1HP&times;1&nbsp;</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Warming Up Time</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>About 160 min(Setting Temperature:265℃)</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>PCB Transmission Speed</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>300~1800mm/min</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Width Range of PCB</td>
<td style=”width: 680.812px; height: 21px;” width=”275″>50-610mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>PCB Board Component Height</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>Top 120mm, Bottom 25mm</td>
</tr>
<tr style=”height: 26px;”>
<td style=”width: 442.188px; height: 26px;” width=”214″>PCB Inlet Transport Height</td>
<td style=”width: 680.812px; height: 26px;” width=”1381″>750&plusmn;20mm</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Transport Guide Rail Inclination</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>Factory:5.5&deg;&plusmn;0.2&deg;(4&deg;&mdash; 7&deg;Adjustable )</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Cooling Mode</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>Forced Air Cooling</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Nitrogen Consumption</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>18m&sup3;/h below 2000ppm以下</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Pressure Nitrogen Source</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>0.5~0.8MPa</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Oxygen Nitrogen Source</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>&le;10PPM</td>
</tr>
<tr style=”height: 21px;”>
<td style=”width: 442.188px; height: 21px;” width=”214″>Oxygen Analyzer</td>
<td style=”width: 680.812px; height: 21px;” width=”1381″>option</td>
</tr>
<tr>
<td style=”width: 1123px;” colspan=”2″>The above contents are subject to change without further notice!</td>
</tr>
</tbody>
</table>

FEATURED PRODUCTS

Scroll to Top

Get Free Quote