Solder paste height measurement equipment is used in PCB assembly to ensure precise deposition of solder paste. Utilizing laser or optical sensors, it scans the paste deposits to measure height, volume, and uniformity. Key features include high-speed inspection, micron-level accuracy, and 3D imaging for defect detection. This equipment helps prevent defects like bridging or insufficient solder, improving SMT process quality. Advanced models integrate with SPI (Solder Paste Inspection) systems for real-time feedback and process optimization. Ideal for high-volume production, it enhances yield and reduces rework in electronics manufacturing.
| Model | REFINE-XS |
| Inspection Module | |
| Camera Specification | 5M High-frequency Industrial Camera, High Frame Number (Factory Setting); 12M Option |
| Pixel | 20μm, 15μmꢀ(Factory Setting) |
| FOV(single field of view) Range | 40×40 mm, 30×30 mm (Factory Setting) |
| LED | RGB + TOP |
| Light Source | 0 – 550 μm |
| Height Inspection Resolution | 0.36 μm |
| Height Inspection Accuracy | 1μm (Based on the actual solder paste/calibration block) |
| Inspection Item | Volume, Area, Height, X/Y Position, Bridging, Shape, etc |
| Defective Type | Excessive/Insufficient/Missing paste,Bridge,2D & 3D Paste displacement, Shape deformity, Dust, etc |
| Repeatability (Volume, Area, Height) | <1% @3sigma |
| GR & R (Gauge Reproducebility and Repeatability) | < 10% (@6sigma tolerance = +/- 50%) |
| Inspection Speed | 0.35Sec / FOV |
| Conveyor & PCB Size | |
| Max PCB Size | 460×410 mm |
| Min PCB Size | 50×50 mm |
| PCB Up-Clearance | 30 mm |
| PCB Bottom-Clearance | 30 mm |
| PCB Thickness | 0.5-5 mm |
| Max PCB Warpage | ±3 mm |
| PCB Transfer Height | 2.5mm |
| PCB Transfer Height | 900±20 mm |
| Max PCB Weight | 5KG |
| Frame & Others | |
| Base & Frame | Integra1 steel casmting frame; firmly, ensure high accuracy of inspection |
| Dimensions and Weight | 947x1321x1600mm (W x D x H) 950KG |
| Power Supply | AC 220V 1Φ 50/60Hz |
| Power | 2.2KW |
| Communication Interface | SMEMA |
| Air Supply | 4-6bar,5L/min |
| Operating Condition | 5-40℃, 15-90% RH |
| Options | |
| 1. BarcodeReader | 4. Repair Station (PC) |
| 2. 3D Calibration Target | 5. Infared Muti-touch LCD + Voice Control |
| 3. 2D Calibration Glass | 6. Offline Editing Software (License Key) |
| The above contents are subject to change without further notice! | |