The solder paste inspection (SPI) process is a critical step in surface-mount technology (SMT) assembly, ensuring precise solder paste deposition before component placement. Using high-resolution 3D scanning or optical imaging, SPI systems measure paste volume, height, alignment, and shape to detect defects such as insufficient paste, bridging, or misalignment. Automated SPI machines compare results against predefined tolerances and flag discrepancies for correction. By catching defects early, SPI minimizes rework, improves yield, and enhances PCB reliability. The process is vital for high-density electronics manufacturing, where even minor paste variations can lead to soldering failures.
| Model | REFINE-XS |
| Inspection Module | |
| Camera Specification | 5M High-frequency Industrial Camera, High Frame Number (Factory Setting); 12M Option |
| Pixel | 20μm, 15μmꢀ(Factory Setting) |
| FOV(single field of view) Range | 40×40 mm, 30×30 mm (Factory Setting) |
| LED | RGB + TOP |
| Light Source | 0 – 550 μm |
| Height Inspection Resolution | 0.36 μm |
| Height Inspection Accuracy | 1μm (Based on the actual solder paste/calibration block) |
| Inspection Item | Volume, Area, Height, X/Y Position, Bridging, Shape, etc |
| Defective Type | Excessive/Insufficient/Missing paste,Bridge,2D & 3D Paste displacement, Shape deformity, Dust, etc |
| Repeatability (Volume, Area, Height) | <1% @3sigma |
| GR & R (Gauge Reproducebility and Repeatability) | < 10% (@6sigma tolerance = +/- 50%) |
| Inspection Speed | 0.35Sec / FOV |
| Conveyor & PCB Size | |
| Max PCB Size | 460×410 mm |
| Min PCB Size | 50×50 mm |
| PCB Up-Clearance | 30 mm |
| PCB Bottom-Clearance | 30 mm |
| PCB Thickness | 0.5-5 mm |
| Max PCB Warpage | ±3 mm |
| PCB Transfer Height | 2.5mm |
| PCB Transfer Height | 900±20 mm |
| Max PCB Weight | 5KG |
| Frame & Others | |
| Base & Frame | Integra1 steel casmting frame; firmly, ensure high accuracy of inspection |
| Dimensions and Weight | 947x1321x1600mm (W x D x H) 950KG |
| Power Supply | AC 220V 1Φ 50/60Hz |
| Power | 2.2KW |
| Communication Interface | SMEMA |
| Air Supply | 4-6bar,5L/min |
| Operating Condition | 5-40℃, 15-90% RH |
| Options | |
| 1. BarcodeReader | 4. Repair Station (PC) |
| 2. 3D Calibration Target | 5. Infared Muti-touch LCD + Voice Control |
| 3. 2D Calibration Glass | 6. Offline Editing Software (License Key) |
| The above contents are subject to change without further notice! | |